Título : Validación del método analítico para la determinación de valsartán en plasma humano por HPLC/UV con adición de estándar empleando losartán como estándar interno
Otros títulos: Validation of an analytical method for the determination of valsartan in human plasma by HPLC/UV with addition standard using losartan as an internal standard
Autores: Pérez, Milena
Ramírez, Gloria
Pérez, Mauricio
Restrepo, Piedad
Palabras clave : Valsartán
Losartán
Extracción en fase sólida
Método de adición de estándar
HPLC/UV
Solid-phase extraction
Addition standard method
HPLC/UV
Fecha de publicación: 11-jul-2013
Resumen: Introducción: El concepto de validación se refiere a la evaluación estadística de los resultados obtenidos en la aplicación de técnicas analíticas, mediante pruebas convenientemente documentadas y demostrativas de que un método es lo suficientemente fiable a fin de producir el resultado previsto bajo condiciones definidas, como son: sistema analítico, intervalo de concentración, infraestructura y talento humano. Objetivo: Describir el proceso de validación del método analítico para la cuantificación de valsartán en plasma humano por HPLCUV y su aplicación en estudios farmacocinéticos, de biodisponibilidad y bioequivalencia de medicamentos que contengan valsartán como principio activo. Metodología: Se desarrolló un método para la detección y cuantificación de valsartán en plasma humano, con elución isocrática por cromatografía líquida de fase reversa, con detección ultravioleta a 265 nm, mediante el método de adición de estándar. Se utilizó losartán como estándar interno. El método implica una extracción en fase sólida de los principios activos ( valsartán y losartán) con cartuchos C8. La separación se realizó en una columna C18 en fase reversa y la fase móvil fue una mezcla de acetonitrilo: buffer fosfato (45:55 v/v) ajustado a pH 2.7±0.1 con ácido fosfórico concentrado. El método se validó en el rango de concentraciones de 0.05 a 20 μg/ml con adición de estándar de valsartán de 2.5 μg/ml. Resultados y conclusiones: La curva de calibración fue lineal en el rango de concentraciones establecido. Se evaluó la reproducibilidad, estabilidad y porcentaje de recuperación del método. El método para determinar el valsartán en plasma humano por HPLC/UV fue preciso y exacto con un límite de cuantificación de 1.485 μg/ml. Este método fue suficientemente sensible para su aplicación en estudios farmacocinéticos de valsartán. Introduction: The validation concept refers to the statistical evaluation of the results obtained in the application of analytic technics, by appropriately documented and demonstrative tests that a method is sufficiently reliable to produce the result foreseen under defined conditions, like they are: analytic system, concentration interval, infrastructure and human talent. Objective: To describe the validation process of the analytic method for the valsartan quantification in human plasma by HPLCUV and its application in pharmacokinetic, bioavailability and bioequivalence studies of products that contain the active principle valsartan. Methodology: A method for detection and quantification of valsartan in human plasma has been developed using an isocratic elution on reversed phase liquid chromatography with ultraviolet detection at a single wavelength (265 nm) and the addition standard method. Losartan was used as an internal standard. This method involves a solid-phase drug extraction (valsartan and losartan) from plasma using C8 cartridges. Separation was achieved on a C18 reversed phase column and the mobile phase consisted of 45% acetonitrile and 55% phosphate buffer (adjusted to pH 2.7 ± 0.1 with phosphoric acid). The assay has been validated over a concentration range of 0.05 to 20 μg/ml with addition of valsartan 2.5 μg/ml. Results and conclusions: Calibration curve was linear in the described concentration range. The reproducibility, stability and recovery of the method were evaluated. Determination of valsartan in human plasma by HPLC/UV method was accurate and precise with a quantitation limit of 1.485 μg/ml. The method was sufficiently sensitive for pharmacokinetic studies of valsartan in human plasma.
URI: http://hdl.handle.net/10893/4700
Aparece en las colecciones: Vol. 38 no. 1, 2007 / Colombia Médica

Texto completo:

Archivo Descripción Tamaño Formato
Validation of an analytical.pdf118.4 kBAdobe PDFDescargar aquí
Ver estadísticas

Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Creative Commons

Los ítems de Biblioteca Digital están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Biblioteca Mario Carvajal
biblioteca@univalle.edu.co
Teléfonos +57 2 3212950 - Fax 3212977
Universidad del Valle - Ciudad Universitaria
Calle 13 # 100-00 Cali, Colombia
    Biblioteca San Fernando
biblioteca@univalle.edu.co
Teléfonos +57 2 5185633 - Fax 5581951
Universidad del Valle - Sede San Fernando
Calle 4a.B # 36-00
Cali, Colombia
    Biblioteca Colección Clínica
biblioteca@univalle.edu.co
Teléfonos +57 2 5576113
Hospital Universitario del Valle
Calle 5a # 36-08
Cali, Colombia
DSpace Software Copyright © 2002-2008 MIT and Hewlett-Packard