Universidad del Valle Biblioteca Digital

Biblioteca Digital Universidad del Valle > Patrimonio Documental Universidad del Valle > Revistas > Ingeniería y Competitividad > Vol. 16 no. 2, 2014 / Ingeniería y Competitividad >

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10893/8496

Título : Impacto de los sólidos suspendidos totales sobre la obstrucción en emisores de riego localizado de alta frecuencia
Otros títulos: Impact of total suspended solids on the emitters clogging of localized high-frequency irrigation
Autores: Sánchez, Luis D.
Viáfara, Christian A.
Palabras clave : Coeficiente de uniformidad
riego localizado de alta frecuencia
sólidos suspendidos
localized high frequency irrigation
total suspended solids
uniformity coefficient
Fecha de publicación: 21-may-2015
Resumen: Resumen Este estudio a escala piloto evaluó el impacto de los sólidos suspendidos totales, SST, sobre la obstrucción en emisores de riego localizado de alta frecuencia, RLAF, empleando como tratamiento para mejorar la calidad de agua un filtro de grava de flujo ascendente con mantas sintéticas (FGAC Manta). El efluente de dicho tratamiento alimentó cuatro tipos de sistemas RLAF: Lyn, Autocompensado, Microjet y Cinta de riego, para evaluar la incidencia del aporte de los SST sobre cada uno de ellos. Para ello se evaluó el riesgo de obturación, el coeficiente de uniformidad (Cu), la concentración de sólidos depositados en las paredes de los conductos y el tamaño de partícula que ingresó a los RLAF. Los resultados mostraron que cuanto mayor fue la concentración de SST, menor fue el tiempo de riego alcanzado por las tecnologías RLAF. La relación de los SST aportados a los RLAF con el tamaño de partícula que ingresó a los conductos y emisores presentó partículas hasta de 129 micras, que contribuyen a la obturación de los emisores. El régimen laminar contribuye a la deposición de sólidos en los conductos de los emisores de las tecnologías RLAF afectando el Cu. Abstract In this pilot study was evaluated the impact of total suspended solids, TSS, take in to account the obstruction on emitters of localized high frequency irrigation technologies, LHFI, using as a treatment upflow gravel filter with synthetic blankets (UGF-Sb) to improve the water quality to the LHFI. The effluent from such treatment systems fed four types of LHFI: lyn, pressure compensate, microjet and drip tape, to assess the impact of TSS on each of them. In this study was evaluated: the clogging risk, uniformity coefficient (Uc) of each LHFI technology, the deposited solids on the walls of the ducts and the influent particle size to the LHFI. Results showed that for greater concentration of TSS, was lower the irrigation time achieved by each LHFI technologies. The relationship between TSS and particle size effluent in LHFI indicated that maximum particle size introduced to the LHFI was 129 microns, which contribute to the emitter clogging. The laminar flow contribute to the deposition of solids in the ducts with impacts on Uc.
URI: http://hdl.handle.net/10893/8496
Aparece en las colecciones: Vol. 16 no. 2, 2014 / Ingeniería y Competitividad

Texto completo:

Archivo Descripción Tamaño Formato
impacto de los solidos.pdf1.5 MBAdobe PDFDescargar aquí
Ver estadísticas

Los ítems de Biblioteca Digital están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Biblioteca Mario Carvajal
biblioteca@univalle.edu.co
Teléfonos +57 2 3212950 - Fax 3212977
Universidad del Valle - Ciudad Universitaria
Calle 13 # 100-00 Cali, Colombia
    Biblioteca San Fernando
biblioteca@univalle.edu.co
Teléfonos +57 2 5185633 - Fax 5581951
Universidad del Valle - Sede San Fernando
Calle 4a.B # 36-00
Cali, Colombia
    Biblioteca Colección Clínica
biblioteca@univalle.edu.co
Teléfonos +57 2 5576113
Hospital Universitario del Valle
Calle 5a # 36-08
Cali, Colombia
DSpace Software Copyright © 2002-2008 MIT and Hewlett-Packard