Methodology for the adjustment of the function of the unbalanced load loss protection - negative ansi 46 sequence of a SIEMENS 7UM62 relay synchronous generator
| dc.contributor.author | Caicedo D., Gladys | |
| dc.contributor.author | Aristizabal, Alexander | |
| dc.date.accessioned | 2020-09-22T14:24:58Z | |
| dc.date.available | 2020-09-22T14:24:58Z | |
| dc.date.issued | 2019-01-30 | |
| dc.description.abstract | (Eng) This paper presents the theory and methodology for the adjustment of the negative sequence current protection function (PF) ANSI 46 of a synchronous generator with poles and poles, for a multifunctional relay SIEMENS 7UM62 that uses for its logic of decision the curve of time of heating allowed of the machine before the in - crease of the magnitude of negative sequence Also the consequences and the damages that can be caused by the excess of current of negative sequence circulating by the stator of the generator are explained. In addition, its functional diagram is illustrated by identifying its input signals: data (settings), analog and bi - nary signals; It also describes in detail its decision process and exit signals. This logical diagram was divided into 3 sub-diagrams to identify the causes that originate their outputs: alarms, startup, firing or blocking, this way of illustrating the process by stages allows greater clarity, since the explanation process is more didactic than the one presented by the manufacturer in the manual. As an example of an illustration, the calculations of the adjustment criteria of the ANSI 46 PF applied to a salient pole generator from Unit 1 of the Salvajina Hydroelectric Plant are presented in detail. This protection function protects the machine by heating load imbalance and asymmetric faults. | spa |
| dc.description.abstract | (Spa) En este artículo se presenta la teoría y la metodología para el ajuste de la función de protección de corriente de secuencia negativa ANSI 46 de un generador sincrónico de polos salientes y de polos lisos, para un relé mul - tifuncional SIEMENS 7UM62 que utiliza para su lógica de decisión la curva de tiempo de calentamiento per - mitido de la máquina ante el incremento de la magnitud de secuencia negativa. También se explican las conse - cuencias y los daños que puede provocar el exceso de corriente de secuencia negativa circulando por el estator del generador. Además, se ilustra su diagrama funcional identificando sus señales de entradas: datos (ajustes), señales análogas y binarias; también se describe en detalle su proceso de decisión de acuerdo a sus valores de sus entradas. Este diagrama lógico se dividió en 3 sub-diagramas para identificar las causas que originan sus salidas de: alarmas, arranque, disparos o bloqueo, esta forma de ilustrar el proceso por etapas permite mayor claridad, ya que el proceso de explicación es más didáctico que el presentado por el fabricante en el manual. Como Ejemplo de ilustración se presentan en detalle los cálculos de los criterios de ajuste de la FDP ANSI 46 aplicados para un generador de polos salientes de la Unidad 1 de la Central Hidroeléctrica de Salvajina. Esta funcion de protección, protege la máquina por calentamiento de desbalance de carga y fallas asimétricas. | spa |
| dc.format.mimetype | application/pdf | spa |
| dc.identifier.uri | https://hdl.handle.net/10893/17935 | |
| dc.language.iso | eng | spa |
| dc.publisher | Universidad del Valle | spa |
| dc.publisher.place | Colombia | spa |
| dc.relation.citationendpage | 89 | spa |
| dc.relation.citationissue | Núm. 1 (2019) | spa |
| dc.relation.citationstartpage | 63 | spa |
| dc.relation.citationvolume | Vol. 21 Núm. 1 (2019) | spa |
| dc.relation.ispartofjournal | Revista Ingeniería y Competitividad | spa |
| dc.relation.ispartofseries | Revista Ingeniería y Competitividad / Vol. 21 Núm. 1 (2019); | |
| dc.rights.accessrights | info:eu-repo/semantics/closedAccess | spa |
| dc.subject.lemb | ANSI 46 | |
| dc.subject.lemb | Protecciones eléctricas | |
| dc.subject.lemb | Generador sincrónico | |
| dc.subject.proposal | ANSI 46 | spa |
| dc.subject.proposal | Electrical protections | spa |
| dc.subject.proposal | Synchronous generator | spa |
| dc.title | Methodology for the adjustment of the function of the unbalanced load loss protection - negative ansi 46 sequence of a SIEMENS 7UM62 relay synchronous generator | spa |
| dc.title.translated | Metodologia para el ajuste de la función de la protección pérdida de carga desequilibrada - secuencia negativa ansi 46 de un generador sincrónico de un relé SIEMENS 7UM62 | |
| dc.type | Artículo de revista | spa |
| dc.type.coar | http://purl.org/coar/resource_type/c_6501 | spa |
| dc.type.content | Text | spa |
| dc.type.driver | info:eu-repo/semantics/article | spa |
| dc.type.redcol | http://purl.org/redcol/resource_type/ARTCORT | spa |
| dc.type.version | info:eu-repo/semantics/publishedVersion | spa |
| dspace.entity.type | Publication | |
| oaire.accessrights | http://purl.org/coar/access_right/c_14cb | spa |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Metodologia para el ajuste.pdf
- Tamaño:
- 705.19 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 14.48 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción:
